400G RX integrated optical subassembly integrates all optical components at the RX end of the high-speed optical transceiver module, including Receptacle, Collimator, Z-block, Lens array, and Prism. Based on the Z-block technology platform, the assembly and coupling of high-speed optical transceiver modules are greatly simplified.
It can be CWDM or LAN-WDM, and the switch only needs to replace the Z-BLOCK component based on TFF technology.
√ With professional optical simulation and analysis capabilities
√ With precision alignment coupling and test capabilities
√ With advanced back-end processing for AWG wafers
400G RX Optical Engine has precise pitch value and error, the pitch can be 500um±3um, 750um±3um (customizable). The Beam size is less than 11um, which can be perfectly matched with PD arrays.
Comply with Telcordia GR-468-core standard, and also meet the requirements of HAST 105℃ RH 100% 168H test.
Parameters | Unit | Specifications (CWDM) | Specifications (LAN-WDM) |
Operating Wavelength Range | nm | 1260~1360 | 1260~1360 |
Channels | - | 4CH | 4CH |
Channel Spacing | / | 20 nm | 800GHz |
Center Wavelength L0/L1/L2/L3 | nm | 1271/1291/1311/1331 | 1295.56/1300.05/1304.58/1309.14 |
Passband (1 dB) | nm | ≥CW±6.5 | ≥CW±1.1 |
Insertion Loss @ passband | dB | ≤1.0 | ≤1.0 |
IL Uniformity | dB | ≤0.6 | ≤0.6 |
Adjacent Channel Isolation | dB | 26 | 26 |
Total Crosstalk | dB | 25 | 25 |
Return Loss | dB | 40 | 40 |
Ripple @ passband | dB | ≤0.8 | ≤0.8 |
Polarization Dependent Loss@ passband | dB | ≤0.25 | ≤0.25 |
Output Beam Angle in Air, AOI_X | deg | 0+/-0.5 | 0+/-0.5 |
Output Beam Angle in Air, AOI_Y | deg | 9 +/-0.5 | 9 +/-0.5 |
Output Beam Diameter @ PD | um | 11 for reference | 11 for reference |
Output Beam Pitch X | um | 750±3 | 750±3 |
Operation Temperature | °C | 0~+75 | 0~+75 |
Storage Temperature | °C | - 40 ~ + 85 | - 40 ~ + 85 |
Thanks for your visiting. For volume needs, please submit your requirements to us.
We will reply to you soon.
Sales Support: sales@hyc-system.com     